Section 16.1
Overview of Ignition System
The Series 60G engine uses a distributorless ignition system (DIS) to initiate combustion and to control combustion timing. The ECM controls dwell time as a function of supply voltage and ignition timing for all speeds and load conditions. The spark event is controlled based on a magnetic pick-up on the crankshaft so it is not necessary to adjust ignition timing.
Series 60 Service Manual - 6SE483 |
Generated on 10-13-2008 |