Section 17.2
Connectors
The DDEC V ECM/ECU has two 68-pin Tyco connectors - one for the engine and the other for the vehicle. Each connector has 60 18 AWG terminals and eight 14 AWG terminals (see Figure "ECM/ECU 68-pin Tyco Connector" ).

Figure 1. ECM/ECU 68-pin Tyco Connector
The EH 68-pin Tyco connector pinout is listed in Table "Series 60 Engine Harness Connector - Pins E-1 Through E-32" and Table "Series 60 Engine Harness Connector - Pins E-33 Through E-68" .
The VIH 68-pin Tyco connector pinout is and Table "Series 60 VIH Connector On-highway Trucks – Pins V-32 – V-68" .
The 68-pin connector center screw must be torqued to 50 in·lb (5.6 N·m)
The shroud is required to protect the connectors from dirt and direct spray and to route the wires in the correct orientation.
If a replacement wire and/or terminal is required, the wires will arrive assembled with the terminals crimped on the wires (see Figure "68 Pin Connector Wires and Terminals" ).

Figure 2. 68 Pin Connector Wires and Terminals
Section 17.2.1
Data Link Connector
The SAE J1708/J1587 nine-pin data link connector is required. DDC recommends that the OEM-supplied Data Link Connector be conveniently positioned in a well protected location facilitating subsequent DDDL usage (i.e., reprogramming, diagnostics, etc.).
The components listed in Table "Required Components to Incorporate an SAE J1939/J1587 Data Link in the VIH" are required to incorporate a SAE J1939/J1587 Data Link in a VIH for diagnostic and reprogramming devices.
Component |
DDC Part Number |
Deutsch Part Number |
Nine-pin Deutsch Connector |
23529496 |
HD10-9-1939P |
Connector Cover |
23529497 |
HDC 16–9 |
Two (2) Cavity Plugs |
23507136 |
114017 |
Seven (7) Terminals |
23507132 |
0460-202-16141 |
The following illustration shows the wiring for the nine-pin connector (see Figure "Wiring for 9-pin Data Link Connector" ).

Figure 3. Wiring for 9-pin Data Link Connector
The maximum length for the SAE J1939 Data Link is 130 ft (40 m).
The SAE J1587/J1708 Data Link must be twisted pairs. The twists are a minimum of 12 turns per foot (305 mm). The maximum length for the SAE J1587/J1708 Data Link is 130 ft (40 m).
Series 60 DDEC V Troubleshooting Guide - 6SE570 |