MBE 900 DDEC VI Troubleshooting – Section 35.1 SPN 175/FMI 2

Section 35.1
SPN 175/FMI 2

This diagnosis is typically engine oil temperature out of range (drifted low/high).‪

Note: When diagnosing rationality erratic data faults (FMI 2) always refer to SILs or SIBs or any known issues first.

Section 35.1.1
Rationality Check for Temperature Drift

Check as follows:‪

  1. Check engine oil level. Add oil if needed and recheck for fault codes. If SPN 175/FMI 2 is still active, go to step 2 .
  2. Disconnect the Engine Oil Temperature Sensor.
  3. Inspect the Engine Oil Temperature Sensor for bent, spread or corroded pins. If pin damage is found, repair as necessary or replace the sensor. Refer to "35.1.1.1 Verify Repairs" .
    Click to see this graphic in a separate window

    Figure 1. Engine Oil Temperature Sensor

Section 35.1.1.1
Verify Repairs

Verify repairs as follows:‪

  1. Turn ignition OFF.
  2. Reconnect any electrical connections that were disconnected to perform the diagnosis.
  3. Clear codes with DDDL 7.0 or latest version.
  4. Start and bring engine up to operating temperature (over 140°F/60°C).
  5. Verify operation is satisfactory and no warning lamps illuminate. If warning lamps illuminate, troubleshoot the codes. If assistance is required, call the Detroit Diesel Customer Support Center at 313–592–5800.