Section 57.3
SPN 641/FMI 9
This code typically means the Smart Remote Actuator 5 is in Failsafe Mode, Motor Off.
Section 57.3.1
Actuator Check
Check as follows:
- Disconnect the turbo actuator.
- Inspect the turbo actuator connector and harness for damaged, bent or spread pins.
- If damage is found, repair as necessary. Refer to "57.3.1.1 Verify Repairs" .
- If no damage is found, go to the next step.
- Disconnect the MCM 120–pin connector.
- Measure the resistance between pin 3 of the turbo actuator harness connector and pin 74 of the MCM 120–pin connector.
- If the resistance is greater than 3 Ω, repair the open circuit between pin 3 of the turbo actuator harness connector and pin 74 of the MCM 120–pin connector. Refer to "57.3.1.1 Verify Repairs" .
- If the resistance is less than 3 Ω, go to the next step.
- Measure the resistance between pin 4 of the turbo actuator harness connector and pin 75 of the MCM 120–pin connector.
- If the resistance is greater than 3 Ω, repair the open circuit between pin 4 of the turbo actuator harness connector and pin 75 of the MCM 120–pin connector. Refer to "57.3.1.1 Verify Repairs" .
- If the resistance is less than 3 Ω, replace the turbo actuator. Refer to "57.3.1.1 Verify Repairs" .
Section 57.3.1.1
Verify Repairs
Verify repairs as follows:
- Turn ignition OFF.
- Reconnect any electrical connections that were disconnected to perform the diagnosis.
- Clear codes with DDDL 7.0 or latest version.
- Start and bring engine up to operating temperature (over 140°F/60°C).
- Verify operation is satisfactory and no warning lamps illuminate. If warning lamps illuminate, troubleshoot the codes. If assistance is required, call the Detroit Diesel Customer Support Center at 313–592–5800.