DD15 Troubleshooting – Section 127.2 SPN 3695/FMI 13

Section 127.2
SPN 3695/FMI 13

This fault is typically one of the following: .‪

  • DPF Regen Inhibit Switch message contains a Signal Not Valid (SNV) indicator
  • DPF Regen Force Switch message contains a Signal Not Valid (SNV) indicator

Check as follows:‪

  1. Check for multiple codes:
    1. If CPC SPN 168/FMI 0/14/18 (Battery Voltage) are present troubleshoot and repair these first.
    2. If MCM SPN 625/FMI 9 is present, troubleshoot and repair the CAN line.
    3. If only a “J1939 Error” fault is present, go to step 2 .
  2. Has the CPC been recently reprogrammed?
    1. If yes, check the proper configuration of the CPC.
    2. If no, connect ServiceLink to determine which modules are configured for the vehicle and their communication status. Once this is done, follow the appropriate module communication troubleshooting procedures for the affected module.


EPA07 DD15 Troubleshooting Guide - DDC-SVC-MAN-0029
Generated on 10-13-2008