Section 5.9
Extended Crank Time
There are no fault codes present and the engine finally starts after an extended crank time.
Check as follows:
- Visually inspect fuel tank for proper fuel level. If the tank is low/empty, fill the tank and verify repair. If fuel level is OK, go to next step.
- Visually inspect the entire fuel system for leaks and damage. Repair as necessary. If no leaks are found, check fuel pressure. Refer to , “Fuel Pressure Test.”
EPA07 MBE 4000 DDEC VI Troubleshooting Guide - 6SE568 |
Generated on 10-13-2008 |