Section 127.1
SPN 3695/FMI 9
This fault is typically one of the following:
- DPF Regen Inhibit Switch message stopped arriving
- DPF Regen Force Switch message stopped arriving
Section 127.1.1
Missing DPF Regen Inhibit Switch or Force Switch Message Check
Check as follows:
- Check for multiple codes:
- If CPC SPN 168/FMI 0/14/18 (Battery Voltage) are present troubleshoot and repair these first.
- If MCM SPN 625/FMI 9 is present, troubleshoot and repair the CAN line.
- If only a “J1939 Error” fault is present, go to step 2 .
- Has the CPC been recently reprogrammed?
- If yes, check the proper configuration of the CPC.
- If no, connect ServiceLink to determine which modules are configured for the vehicle and their communication status. Once this is done, follow the appropriate module communication troubleshooting procedures for the affected module.
EPA07 MBE 4000 DDEC VI Troubleshooting Guide - 6SE568 |
Generated on 10-13-2008 |