MBE 900 DDEC VI Troubleshooting – Section 54.1 SPN 630/FMI 14

Section 54.1
SPN 630/FMI 14

This fault code indicates a communication interruption between the CPC and MCM. It is caused by either of the following:‪

  • DDDL connecting to the CPC/MCM at a specific time within the first few seconds of Ignition ON, and remaining connected for over 10 minutes
  • Sending parameters to the CPC while connected to both the CPC and MCM, and DDDL remaining connected for over 10 minutes

The only required action is to disconnect DDDL, cycle the Ignition switch then reconnect DDDL.‪


EPA07 MBE 900 DDEC VI Troubleshooting Guide - 6SE580
Generated on 10-13-2008

One Reply to “MBE 900 DDEC VI Troubleshooting – Section 54.1 SPN 630/FMI 14”