Section 68.3
SPN 709/FMI 5
This fault code indicates that there is an open circuit.
Section 68.3.1
Open Circuit Check
Check for open as follows:
- Disconnect the fan control solenoid connector.
- Turn the ignition to the ON position.
- Measure the voltage between pin 1 and 2 of the fan control solenoid connector.
- If the voltage is less than 11.5 volts, go to step 4 .
- If the voltage is between 11.5 and 13.5 volts, replace the fan control solenoid. Refer to "68.3.1.1 Verify Repairs" .
- Measure the voltage between pin 2 of the fan control solenoid connector and pin 91 of the 120–pin MCM connector. Refer to "68.3.1.1 Verify Repairs"
.
- If the voltage is less than 11.5 volts, repair the open between pin 2 of the fan control solenoid connector and ground. Refer to "68.3.1.1 Verify Repairs" .
- If the voltage is greater than 11.5, repair the open between pin 1 of the fan control solenoid connector and pin 98 of the 120–pin MCM connector. Refer to "68.3.1.1 Verify Repairs" .
Section 68.3.1.1
Verify Repairs
Verify repairs as follows:
- Turn ignition OFF.
- Reconnect any electrical connections that were disconnected to perform the diagnosis.
- Clear codes with DDDL 7.0 or latest version.
- Start and bring engine up to operating temperature (over 140°F/60°C).
- Verify operation is satisfactory and no warning lamps illuminate. If warning lamps illuminate, troubleshoot the codes. If assistance is required, call the Detroit Diesel Customer Support Center at 313–592–5800.