Section 72.3
SPN 715/FMI 5
Vehicle Power Shutdown - indicates a open circuit on the pin 10 circuit of the CPC #4 connector. For wiring schematic information refer to OEM literature.
Note: The CPC digital outputs have the same SPN as some MCM faults. DDDL 7.0 makes the distinction between the MCM and CPC when diagnosing a fault.
EPA07 MBE 900 DDEC VI Troubleshooting Guide - 6SE580 |
Generated on 10-13-2008 |