Section 95.2 
SPN 2630/FMI 4
This diagnostic condition is typically intake air temperature circuit failed low.

Repair the short to ground between pin 2 of the Intake Air Temperature Sensor harness connector and pin 119 of the MCM 120–pin connector. Refer to "95.2.1 Verify Repairs" .
Section 95.2.1 
Verify Repairs
Verify repairs as follows:
- Turn ignition OFF.
- Reconnect any electrical connections that were disconnected to perform the diagnosis.
- Clear codes with DDDL 7.0 or latest version.
 ENGINE EXHAUST  To avoid injury from inhaling engine exhaust, always operate the engine in a well-ventilated area. Engine exhaust is toxic. 
- Start and bring engine up to operating temperature (over 140°F/60°C).
- Verify operation is satisfactory and no warning lamps illuminate. If warning lamps illuminate, troubleshoot the codes. If assistance is required, call the Detroit Diesel Customer Support Center at 313–592–5800.
| EPA07 DD15 Troubleshooting Guide - DDC-SVC-MAN-0029 | 
| Generated on 10-13-2008 |