MBE 900 – Section 10.4 EGR/Ca Mixer Housing

Section 10.4
EGR/Ca Mixer Housing

Section 10.4.1
EGR/CA Mixer Housing Removal

Remove the EGR/CA mixer housing as follows (see Figure "EGR/CA Mixer Housing Removal and Installation" for component locations):‪

  1. Remove the charge air intake housing. Refer to "10.3.1 EGR Charge Air Intake Housing Removal" .
  2. Remove the EGR/CA mixer housing cover bolts and remove the gasket and cover. Discard gasket.
  3. Remove two hexagon socket-head head screws securing the EGR/CA mixer tube inside the charge air intake housing.
    Click to see this graphic in a separate window

     1. Charge Air Intake Housing‪

     5. Delivery Pipe‪

     2. EGR/CA Mixer Housing Cover Bolts‪

     6. EGR/CA Mixer Tube‪

     3. EGR/CA Mixer Housing Cover‪

     7. Hexagon Socket-head Screw‪

     4. Delivery Pipe Gasket‪

     ‪

    Figure 1. EGR/CA Mixer Housing Removal and Installation

Section 10.4.2
EGR/CA Mixer Housing Installation

Install the EGR/CA mixer housing as follows (see Figure "EGR/CA Mixer Housing Removal and Installation" for component locations):‪

  1. Install EGR/CA mixer tube in charge air intake housing with two hexagon socket-head screws. Tighten screws to 12–14 N·m (9–10 lb·ft).
  2. Install charge air housing. Refer to "10.3.2 EGR Charge Air Intake Housing Installation" .


MBE 900 Service Manual - 6SE414
Generated on 10-13-2008

Leave a Reply