Section 75.1
SPN 729/FMI 3
This diagnosis is typically a short to power/open.
Section 75.1.1
Short to Power/Open Check
Check as follows:
- Disconnect the Grid Heater connector.
- Turn the ignition ON (key ON, engine OFF).
- Measure the voltage between pins 2 and 4 of the Grid Heater connector. See Figure
"Grid Heater Wiring"
.
Figure 1. Grid Heater Wiring
- If the voltage is greater than 11.5 volts, go to step 5 .
- If the voltage is less than 11.5 volts, go to step 4 .
- Measure the voltage between pin 2 of the Grid Heater connector and ground.
- If the voltage is greater than 11.5 volts, repair the open between pin 4 of the Grid Heater connector and pin 95 of the 120–pin MCM connector. Refer to "75.1.1.1 Verify Repairs" .
- If the voltage is less than 11.5 volts, repair the open between pin 2 of the Grid Heater connector and pin 41 of the 120–pin MCM connector. Refer to "75.1.1.1 Verify Repairs" .
- Turn the ignition OFF.
- Disconnect the 120–pin MCM connector.
- Measure the resistance between pins 2 and 3 of the Grid Heater connector.
- If the resistance is greater than 5 Ω, go to step 8 .
- If the resistance is less than 5 Ω, repair the short between Grid Heater pins 2 and 3 and pins 41 and 92 of the 120–pin MCM connector. Refer to "75.1.1.1 Verify Repairs" .
- Measure the resistance between pin 3 of the Grid Heater connector and pin 92 of the 120–pin MCM connector.
- If the resistance is greater than 5 Ω, repair the open between pin 3 of the Grid Heater connector and pin 92 of the 120–pin MCM connector. Refer to "75.1.1.1 Verify Repairs" .
- If the resistance is less than 5 Ω, replace the Grid Heater.
Section 75.1.1.1
Verify Repairs
Verify repairs as follows:
- Turn ignition OFF.
- Reconnect any electrical connections that were disconnected to perform the diagnosis.
- Clear codes with DDDL 7.0 or latest version.
- Start and bring engine up to operating temperature (over 140°F/60°C).
- Verify operation is satisfactory and no warning lamps illuminate. If warning lamps illuminate, troubleshoot the codes. If assistance is required, call the Detroit Diesel Customer Support Center at 313–592–5800.