Section 52.2
SPN 625/FMI 4
This fault is typically erratic data or the CAN propriety data link has failed between the MCM and the CPC.
Note: The following diagnostics pertain to faults received from the MCM and /or the CPC.
Section 52.2.1
Data Link Check
Check as follows:
- Have the MCM and/or the CPC been recently changed or reprogrammed?
- If yes, verify the that the correct MCM calibration and/or the correct CPC parameter list has been installed. If the correct calibration and correct parameter list have been installed, go to the next step.
- If no, go to the next step.
- Disconnect the MCM 21–pin connector.
- Turn the ignition ON (key ON, engine OFF).
- Measure the ignition voltage at pin 7 on the MCM 21–pin connector.
- If the ignition voltage is less than 10.5 volts, restore the ignition voltage at pin 7. Refer to "52.2.1.1 Verify Repairs" .
- If the ignition voltage is greater than 10.5 volts, go to the next step.
- Measure the battery voltage at pins 11, 12, 14, and 15 on the MCM 21–pin connector.
- If the battery voltage is less than 10.5 volts, restore the battery voltage at pins 11, 12, 14, and 15 on the MCM 21–pin connector. Refer to "52.2.1.1 Verify Repairs" .
- If the battery voltage is greater than 10.5 volts, go to the next step.
Note: Poor battery grounds can be a possible cause of low battery voltage.
- Turn ignition OFF, leave the 21–pin MCM connector disconnected.
- Disconnect the CPC #4 connector.
- Measure the resistance between pins 1 and 3 of the CPC #4 connector.
- If the resistance is greater than 5 Ω, go to the next step.
- If the resistance is less than 5 Ω, repair the short circuit in the wires between pins 1 and 3 of the CPC #4 connector and pins 13 and 19 of the 21–pin MCM connector. Refer to "52.2.1.1 Verify Repairs" .
- Measure the resistance between pin 1 of the CPC #4 connector and ground.
- If the resistance is greater than 5 Ω, go to the next step.
- If the resistance is less than 5 Ω, repair the short circuit to ground between pin 1 of the CPC #4 connector and ground. Refer to "52.2.1.1 Verify Repairs" .
- Check the resistance between pin 3 of the CPC #4 connector and ground.
- If the resistance is greater than 5 Ω, go to the next step.
- If the resistance is less than 5 Ω, repair the short circuit to ground between pin 3 of the CPC #4 connector and ground. Refer to "52.2.1.1 Verify Repairs" .
- Measure the resistance between pin 1 of the CPC #4 connector and pin 19 of the 21–pin MCM connector.
- If the resistance is greater than 5 Ω, repair the open circuit between pin 1 of the CPC #4 connector and pin 19 of the 21–pin MCM connector. Refer to "52.2.1.1 Verify Repairs" .
- If the resistance is less than 5 Ω, go to the next step.
- Measure the resistance between pin 3 of the CPC #4 connector and pin 13 of the 21–pin MCM connector.
- If the resistance is greater than 5 Ω, repair the open circuit between pin 3 of the CPC #4 connector and pin 13 of the 21–pin MCM connector. Refer to "52.2.1.1 Verify Repairs" .
- If the resistance is less than 5 Ω, call the DDC Customer Support Center (313–592–5800).
Section 52.2.1.1
Verify Repairs
Verify repairs as follows:
- Turn ignition OFF.
- Reconnect any electrical connections that were disconnected to perform the diagnosis.
- Clear codes with DDDL 7.0 or latest version.
- Start and bring engine up to operating temperature (over 140°F/60°C).
- Verify operation is satisfactory and no warning lamps illuminate. If warning lamps illuminate, troubleshoot the codes. If assistance is required, call the Detroit Diesel Customer Support Center at 313–592–5800.