Series 60 DDEC VI Troubleshooting – Section 109.1 SPN 3510/FMI 2

Section 109.1
SPN 3510/FMI 2

This fault indicates that the throttle pedal supply is receiving erratic data.‪

Section 109.1.1
Erratic Data Check

Check as follows:‪

  1. Disconnect the Accelerator Pedal (AP).
  2. Turn the ignition ON.
  3. Measure the voltage between pins 1 and 3 of the AP harness connector. See Figure "Accelerator Pedal Assembly Installation" .
    Click to see this graphic in a separate window

    Figure 1. Accelerator Pedal Assembly Installation

    1. If the voltage is between 4.5 and 5.5 volts, go to step 5 .
    2. If the voltage is less than 4.5, go to step 4 .
  4. Measure the voltage between pins 1 of the AP harness connector and ground.
    1. If the voltage is between 4.5 and 5.5 volts, repair the open circuit between pin 3 of the AP harness connector and pin 4 of the CPC #1 connector. Refer to "109.1.1.1 Verify Repairs" .
    2. If the voltage is less than 4.5, repair the open circuit between pin 1 of the AP harness connector and pin 8 of the CPC #1 connector. Refer to "109.1.1.1 Verify Repairs" .
  5. Turn the ignition OFF.
  6. Disconnect the CPC #1 connector.
  7. Measure the resistance between pin 2 of the AP harness connector and pin 7 of the CPC #1 connector.
    1. If the resistance is greater than 3 Ω, repair the open between pin 2 of the AP harness connector and pin 7 of the CPC #1 connector. Refer to "109.1.1.1 Verify Repairs" .
    2. If the resistance is less than 3 Ω, replace the Accelerator Pedal. Refer to "109.1.1.1 Verify Repairs" .
Section 109.1.1.1
Verify Repairs

Verify repairs as follows:‪

  1. Turn ignition OFF.
  2. Reconnect any electrical connections that were disconnected to perform the diagnosis.
  3. Clear codes with DDDL 7.0 or latest version.
  4. Start and bring engine up to operating temperature (over 140°F/60°C).
  5. Verify operation is satisfactory and no warning lamps illuminate. If warning lamps illuminate, troubleshoot the codes. If assistance is required, call the Detroit Diesel Customer Support Center at 313–592–5800.