Series 60 DDEC V Troubleshooting – Section 83.6 Snapshot Sequence

Section 83.6
Snapshot Sequence

Start with the Menu Selection screen.‪

  1. Select PRO-LINK and ENTER.
  2. Go up to SNAPSHOT and ENTER.
  3. Go down to DATA UPDATE RATE and ENTER.
  4. Type in NEW RATE and ENTER (.0 to 9.9 seconds), (90 frames will be recorded).
  5. Up to TRIGGER SETUP and ENTER.
  6. Select TRIGGER SOURCE and ENTER:
    1. Any Numeric Key
    2. Any code
    3. Specific PID
    4. Specific SID
  7. Adjust TRIGGER POINT: NO, or select YES and ENTER; change trigger point with RT/LT arrow keys. ENTER.
  8. WAITING FOR TRIGGER. When ready to take SNAPSHOT, apply the trigger. ANY NUMERIC KEY overrides all other triggers.
  9. PROCESSING TRIGGER; Filling remaining frames (90 frames max). When all frames are filled, the first three lines of the TRIGGER FRAME, T, will display.
    1. To do SNAPSHOT after setup is done, do items 1, 2, and 8 only, or go to QUICK TRIGGER and ENTER.
    2. SNAPSHOT DATA stays stored in Pro-Link memory as long as the DDR remains powered up.


Series 60 DDEC V Troubleshooting Guide - 6SE570
Generated on 10-13-2008