Description of Flash Code 12

Flash Code 12 indicates that the Variable Speed Governor (VSG) input to the ECM has exceeded 95% (normally > 4.75 volts) of the sensor supply voltage. This diagnostic condition is typically:‪

  • Open sensor return circuit
  • Sensor signal circuit is shorted to the sensor +5 volt supply
  • Throttle sensor not adjusted properly at full throttle