Flash Code 36 indicates that the engine Oil Pressure Sensor (OPS), see Figure "Oil Pressure Sensor" , input to the ECM has dropped below 5% (normally < 0.25 volts) of the sensor supply voltage.‪

This diagnostic condition is typically:‪

  • Open sensor signal circuit
  • Open sensor +5 volt supply circuit
  • Sensor signal is shorted to sensor return circuit or to ground
  • Sensor +5 volt supply is shorted to the sensor return circuit