Series 50 – Section 13.10 Lubricating Oil and Filter Change Intervals for Genset (With High Sulfur Fuels)

Section 13.10
Lubricating Oil and Filter Change Intervals for Genset (With High Sulfur Fuels)

The following fluids must be maintained at various intervals.‪

NOTICE:

Operation with fuels having total sulfur greater than 32 ppm, on a mass basis, may result in engine damage, and is not recommended by Detroit Diesel Corporation.‪

Section 13.10.1
200 hrs (or 6 months) Interval Maintenance (Standby Duty)

Every 200 hrs (or 6 months), the following must be replaced for an engine on standby:‪

Fuel with total sulfur greater than 17 ppm, but less than 24 ppm.‪

Section 13.10.2
200 hrs (or 3 months) Interval Maintenance (Continuous Duty)

Every 200 hrs (or 3 months), the following must be replaced for a continuous running engine:‪

Fuel with total sulfur greater than 17 ppm, but less than 24 ppm.‪

Section 13.10.3
150 hrs (or 3 months) Interval Maintenance (Standby Duty)

Every 150 hrs (or 3 months), the following must be replaced for a engine on standby:‪

Fuel with total sulfur greater than 24 ppm, but less than 32 ppm.‪

Section 13.10.4
150 hrs (or 3 months) Interval Maintenance (Standby Duty)

Every 150 hrs (or 3 months), the following must be replaced for a engine on standby:‪

Fuel with total sulfur greater than 24 ppm, but less than 32 ppm.‪