Series 60 DDEC V Troubleshooting – Section 78.3 Troubleshooting Flash Code 89, PID 95/FMI 0

Section 78.3
Troubleshooting Flash Code 89, PID 95/FMI 0

Troubleshoot Flash Code 89 p 95/0 indicating that the fuel inlet restriction has exceeded recommended limits using the following procedures.‪

Section 78.3.1
Check Fuel Inlet Restriction

The following procedure will troubleshoot the fuel inlet restriction:‪

  1. Check the fuel filters and replace if plugged or dirty.
  2. Refer to the mechanical troubleshooting sectin of this manual for the reasons for high fuel inlet restriction.